CTDW-145LI FTR01 130 kW diesel generator
Manufacturer | DEUTZ |
---|---|
Model | BF4M1013 FC |
Power (HP/kW) | 173/129 |
Power according to Standard | ISO 14396 |
Rotation Speed (rpm) | 1500 |
Displacement (Liters) | 4.76 |
Number of Cylinders and Configuration | 4 in line |
Bore x Stroke (mm) | 108 x 130 |
Compression Ratio | 17:1 |
Cooling System Type | Liquid |
---|---|
Maximum Ambient Temperature for Radiator (°C) | 50 |
Air Flow for Cooling (m³/h) | 9000 |
Coolant Volume in Engine Block (liters) | 7.4 |
Coolant Volume in Complete System (liters) | 19.7 |
Heat emitted to Coolant (kW) | 62.7 |
Heat for Aftercooler (kW) | 23.7 |
Heat emitted by Engine Surface Radiation (kW) | 13.0 |
Air Intake System Type | Turbo Aftercooler |
---|---|
Air Filter Type | Radial |
Air Intake Flow (at air 1.2 kg/m³) (m³/min) | 482.1 |
Cooler for Air Charge / Water | Yes |
Maximum Oil Capacity in Pan with Filter (liters) | 11 |
---|---|
Oil Change Interval (hours) | 500 |
Minimum Oil Technical Specifications | TR0199-99-1217 |
Factory Oil Viscosity | 15W40 |
Injection Type and Regulation | Electronic |
---|---|
Fuel Consumption at 100% Continuous Load (l/h) | 26.75 |
Fuel Consumption at 75% Continuous Load (l/h) | 19.39 |
Fuel Consumption at 50% Continuous Load (l/h) | 13 |
Charging System | Alternator - 55A |
---|---|
Battery Specifications | V/Amp-hours CCA (Cold Cranking Amps) |
Model | COMAP InteliNano PLUS |
Parameters Displayed on Screen | Generator Parameters: U1-U3, I1 or I2 or I3, Hz Battery Voltage Group Running Hours Analog Oil Pressure: Consult Engine Coolant Temperature: Consult Engine Speed: Consult Fuel Level: Consult |
Parameter Configuration and Time Programming | ⚫ |
---|---|
Alarms | ⚫ |
Start Failure (Stop) | ⚫ |
---|---|
Low Oil Pressure (Stop) | ⚫ |
Overtemperature (Stop) | ⚫ |
Overspeed (Stop) | ⚫ |
Emergency Stop Button Pressed (Stop) | ⚫ |
Generator Overload (Stop) | ⚫ |
Generator Short Circuit (Stop) | ⚫ |
Generator Voltage Out of Limits (Stop) | ⚫ |
Generator Frequency Out of Limits (Stop) | ⚫ |
Belt Breakage or Battery Charger Failure (Stop) | ⚫ |
Low Fuel Level (Warning) | ⚫ |
Low Battery Voltage (Warning) | ⚫ |
Optional Alarm (Warning/Stop) | ⚫ |
Voltage Asymmetry (Stop) Current Asymmetry (Stop) | ⚫ |